{"product_id":"victron-phoenix-inverter-controll-panel","title":"Victron Phoenix Inverter Control Panel","description":"\u003cp\u003eThe Victron Phoenix Inverter Control (REC030001210) is a dedicated remote monitoring and control panel designed for large Phoenix Inverters equipped with a VE.Bus RJ45 UTP remote monitoring and control socket. Connecting to the inverter via a standard UTP cable with RJ45 connectors, it provides LED indication of inverter status and operational control — including on, off, and AES (Automatic Economy Switching) mode selection — from a remote panel location without requiring physical access to the inverter unit itself.\u003c\/p\u003e\n\u003cp\u003eThe panel is also compatible with the MultiPlus Inverter\/Charger when an automatic transfer switch function is required but no charger functionality is needed — providing basic inverter on\/off and AES control across the MultiPlus range in this specific use case. A standard UTP (Ethernet) patch cable of any required length connects the panel to the inverter's RJ45 remote socket — the cable is not included and must be sourced separately.\u003c\/p\u003e\n\u003cp\u003eStatus LEDs on the panel provide an at-a-glance overview of inverter operating state — including mains present, inverter on, low battery, overload, and fault conditions — making it easy to confirm system status from a convenient remote location such as a helm station, electrical panel, or living area. LED brightness is automatically reduced at night by a built-in ambient light sensor, preventing the panel from becoming an unwanted light source in darkened sleeping quarters or accommodation spaces.\u003c\/p\u003e\n\u003cp\u003eCertified to IEC 60335-1, the Phoenix Inverter Control is suitable for use in European and international marine, RV, and off-grid installations. It is compatible with the following Phoenix Inverter models only: 12\/1200, 12\/1600, 12\/2000, 12\/3000, 12\/5000, 24\/1200, 24\/1600, 24\/2000, 24\/3000, 24\/5000, 48\/3000, and 48\/5000. For Phoenix Inverters with a VE.Direct port rather than a VE.Bus RJ45 port, the separate Phoenix Inverter Control VE.Direct panel is required instead.\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003ch4\u003eRemote On\/Off and AES Mode Control\u003c\/h4\u003e\n\u003cp\u003eProvides remote on\/off switching and AES (Automatic Economy Switching) mode selection for compatible Phoenix Inverters — allowing operators to control inverter operation from a convenient remote location without accessing the inverter unit, and enabling AES mode to reduce no-load power consumption during periods of low demand.\u003c\/p\u003e\n\u003ch4\u003eLED Status Indication\u003c\/h4\u003e\n\u003cp\u003eMultiple LEDs display the current inverter operating state — including mains\/grid present, inverter active, low battery warning, overload, and fault conditions — giving an immediate at-a-glance overview of inverter status from wherever the panel is mounted.\u003c\/p\u003e\n\u003ch4\u003eAutomatic LED Brightness Reduction at Night\u003c\/h4\u003e\n\u003cp\u003eA built-in ambient light sensor automatically reduces LED brightness in low-light or dark conditions — preventing the panel from becoming an unwanted light source in sleeping quarters, cabins, or darkened control areas during overnight inverter operation.\u003c\/p\u003e\n\u003ch4\u003eUTP Cable Connection — Any Length\u003c\/h4\u003e\n\u003cp\u003eConnects to the Phoenix Inverter's VE.Bus RJ45 remote monitoring and control socket via a standard UTP (Ethernet) patch cable — allowing the panel to be located at any distance from the inverter using a standard straight-through Ethernet cable of the required length. Cable not included.\u003c\/p\u003e\n\u003ch4\u003eCompatible with MultiPlus for Transfer Switch Control\u003c\/h4\u003e\n\u003cp\u003eCan be used on a MultiPlus Inverter\/Charger when an automatic transfer switch function is required without the charger functionality — providing basic inverter on\/off and AES control across compatible MultiPlus models in this specific configuration.\u003c\/p\u003e\n\u003ch4\u003eIEC 60335-1 Certified\u003c\/h4\u003e\n\u003cp\u003eCertified to IEC 60335-1 for household and similar electrical appliances safety — confirming the panel's suitability for installation in marine, RV, and off-grid installations across European and international markets.\u003c\/p\u003e\n\u003ch4\u003eCompatible with VE.Bus Phoenix Inverters 1200VA and Above Only\u003c\/h4\u003e\n\u003cp\u003eDesigned exclusively for large Phoenix Inverters (1200VA and above) equipped with a VE.Bus RJ45 UTP remote socket — not compatible with smaller Phoenix Inverter models or with Phoenix Inverters featuring a VE.Direct port, which require the separate Phoenix Inverter Control VE.Direct panel.\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable class=\"product-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eREC030001210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Inverters\u003c\/td\u003e\n\u003ctd\u003ePhoenix Inverter 12\/1200, 12\/1600, 12\/2000, 12\/3000, 12\/5000 | 24\/1200, 24\/1600, 24\/2000, 24\/3000, 24\/5000 | 48\/3000, 48\/5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlso Compatible With\u003c\/td\u003e\n\u003ctd\u003eMultiPlus Inverter\/Charger (transfer switch function, no charger control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eUTP cable with RJ45 connector (cable not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Functions\u003c\/td\u003e\n\u003ctd\u003eOn \/ Off \/ AES (Automatic Economy Switching) mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Status Indicators\u003c\/td\u003e\n\u003ctd\u003eMains present \/ Inverter on \/ Low battery \/ Overload \/ Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Night Dimming\u003c\/td\u003e\n\u003ctd\u003eYes - ambient light sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eIEC 60335-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eProduct Dimensions\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Dimensions-of-metal-panel-for-REC030001210-Inverter-Control_v2.0.pdf\" target=\"_blank\"\u003eProduct Dimensions\u003c\/a\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47125546565881,"sku":"IVV50220","price":96.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/8538\/1625\/files\/Product-IVV50220-1.webp?v=1779761070","url":"https:\/\/emarineinc.com\/products\/victron-phoenix-inverter-controll-panel","provider":"eMarine","version":"1.0","type":"link"}