{"product_id":"victron-ve-bus-to-bms-12-200-alternator-control-cable","title":"Victron VE.Bus to BMS 12-200 alternator control cable","description":"\u003cp\u003eThe Victron VE.Bus BMS to BMS 12\/200 Alternator Control Cable (ASS030510120) is a dedicated interconnect cable that enables the alternator charge control feature of the Smart BMS 12\/200 to be used in systems that also incorporate a VE.Bus BMS. Without this cable, the two BMS units operate independently — this cable bridges the charge disconnect signal from the VE.Bus BMS to the Smart BMS 12\/200, allowing the BMS 12\/200 to respond to battery cell alarms generated by the VE.Bus BMS and act accordingly on the alternator circuit.\u003c\/p\u003e\n\u003cp\u003eIn systems where a Victron LiFePO4 battery communicates with a VE.Bus BMS — protecting against cell overvoltage, undervoltage, and overtemperature — the VE.Bus BMS transmits alarm signals to the BMS 12\/200 via this cable. The BMS 12\/200 then limits alternator charge current to a safe value and immediately stops the alternator charging process if the battery issues an alarm, protecting the lithium cells from damage caused by uncontrolled alternator charge current during a cell protection event.\u003c\/p\u003e\n\u003cp\u003eThis cable is essential in installations where both a VE.Bus inverter\/charger system — controlled by the VE.Bus BMS — and an alternator are used as charge sources for the same lithium battery bank. It closes the communication loop between the two BMS units, ensuring that the alternator is subject to the same battery protection logic as the inverter\/charger, without requiring any additional relays, contactors, or manual wiring between the two BMS devices.\u003c\/p\u003e\n\u003cp\u003eNote that in this configuration the DC load output of the BMS 12\/200 is not operational. The Li-ion battery and any loads powered by the Li-ion battery must not be connected to ground in this setup. Please refer to the BMS 12\/200 manual for full installation details and wiring diagrams specific to this cable configuration.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003ch4\u003eBridges VE.Bus BMS and Smart BMS 12\/200 Charge Control\u003c\/h4\u003e\n\u003cp\u003eConnects the charge disconnect output of the VE.Bus BMS to the Smart BMS 12\/200, enabling the BMS 12\/200's alternator charge control feature to respond directly to battery cell alarms generated by the VE.Bus BMS — without additional relays, wiring, or external control logic.\u003c\/p\u003e\n\u003ch4\u003eAlternator Current Limiting and Charge Stop on Alarm\u003c\/h4\u003e\n\u003cp\u003eWhen a battery cell alarm is received from the VE.Bus BMS, the BMS 12\/200 limits alternator charge current to a safe value and stops the alternator charging process immediately — protecting lithium cells from uncontrolled alternator current during a cell overvoltage, undervoltage, or overtemperature event.\u003c\/p\u003e\n\u003ch4\u003eEnables Dual Charge Source Protection in VE.Bus Systems\u003c\/h4\u003e\n\u003cp\u003eAllows systems with both a VE.Bus inverter\/charger (controlled by the VE.Bus BMS) and a vehicle or vessel alternator (controlled by the Smart BMS 12\/200) to share a single unified battery protection logic — ensuring both charge sources respond correctly to the same battery alarm signals.\u003c\/p\u003e\n\u003ch4\u003ePlug-and-Play — No Additional Hardware Required\u003c\/h4\u003e\n\u003cp\u003eConnects directly between the charge disconnect terminal of the VE.Bus BMS and the corresponding input of the Smart BMS 12\/200 with no additional relays, fuses, or control hardware needed — providing a clean, factory-engineered solution for alternator control in dual-BMS lithium systems.\u003c\/p\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003ctable class=\"product-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eASS030510120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Products\u003c\/td\u003e\n\u003ctd\u003eVE.Bus BMS (V1) and Smart BMS 12\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCharge disconnect signal interconnect-VE.Bus BMS to BMS 12\/200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBMS 12\/200 DC Load Output\u003c\/td\u003e\n\u003ctd\u003eNot operational when this cable is used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Note\u003c\/td\u003e\n\u003ctd\u003eLi-ion battery and loads must not be connected to chassis ground in this configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDocument and Manuals\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/VE.Bus-BMS-to-BMS-12-1200-alternator-control-cable-EN.pdf\" target=\"_blank\"\u003eProduct Document\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Manual-BMS-12-200-EN-NL-FR-ES-DE.pdf\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47128042275065,"sku":"BDV30320","price":30.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0783\/8538\/1625\/files\/Product-BDV30320-1.webp?v=1778906616","url":"https:\/\/emarineinc.com\/products\/victron-ve-bus-to-bms-12-200-alternator-control-cable","provider":"eMarine","version":"1.0","type":"link"}