How to Charge a 48V Battery Bank with Solar on an Electric Boat

To charge a 48V battery bank with solar on an electric boat, the panels must deliver more than the roughly 58 V the bank reaches while charging, and a 48V solar charge controller with MPPT must sit between the array and the battery. There are two ways to get that voltage: wire panels in series into a standard MPPT controller, or use a boost MPPT that steps up the output of one low-voltage panel. The right one depends on the flat space available for panels.

Two Ways to Reach 48 V Charging Voltage

Panels in series into a standard MPPT

Most MPPT controllers step voltage down, so the array must be above battery voltage. Wiring panels in series adds their voltages, as shown in Parallel vs Series Solar Panel Connections. Victron's 150 V models, the MPPT 150/35, 150/70 and 150/85, charge 48 V banks this way.

The 48V Electric Drive Solar Charging Kits use this layout: two or four panels of 340 to 450 W with a Victron MPPT, brackets, wire and circuit protection.

A boost MPPT from one low-voltage panel

The Genasun GVB-8 works the other way around: it takes a panel whose voltage is below the battery voltage and steps it up. Sunforge rates it at 8 A of panel current. On a 48 V bank the largest recommended panel is 350 W with a maximum power voltage (Vmp) of 43 V or less. Charging starts with as little as 5 V from the panel, and the maximum input is 60 V.

Two versions fit a 48 V bank: the GVB-8-Pb-48V for lead-acid and the GVB-8-Li-56.8V for 16-cell LiFePO4, both in the Genasun GVB-8 boost range. The standard case is IP40 and must stay dry; the GVB-8-WP is IP68 waterproof. Larger arrays use one controller per panel, all charging the same bank.

How Much Array Voltage a 48 Volt Solar Charge Controller Needs

The minimum: battery voltage plus 5 V

Victron's manuals state that PV voltage must exceed battery voltage by 5 V for the controller to start, and by 1 V to keep running. A 48 V bank in absorption sits at 57.6 V, so the array must reach 62.6 V to start. Because panel voltage drops in heat, Victron calls for at least 144 cells in series on a 48 V battery. That is four 12 V (36-cell) panels or two 24 V (72-cell) panels.

The maximum: Voc on the coldest morning

Open-circuit voltage (Voc) rises in the cold and must never exceed the controller's limit. For the 150/70 and 150/85 Victron gives 150 V as the absolute maximum in the coldest conditions and 145 V as the operating maximum. Use the coefficient from the panel datasheet:

Cold Voc = Voc × (1 + coefficient × degrees C below 25)

Example: six 12 V panels in series, each with a Voc of 22 V and a coefficient of 0.3% per degree C. At 77°F (25°C) the string is at 132 V. At 32°F (0°C) each panel reaches 23.65 V and the string 142 V: inside the limit, with little margin. Four or five panels leave more room.

How Many Watts of 48V Solar Panel Fit on a Small Boat

There is no special 48V solar panel for boats. The voltage comes from the wiring and the watts come from the area. The kit page lists 48 sq ft of flat mounting area for 900 W and 80 sq ft for 1,360 W, which is 17 to 19 W per square foot. A 4 x 6 ft hardtop holds about 400 W and a 6 x 8 ft canopy about 900 W. Sizing Your Marine Solar System covers measuring the space.

Array Size, Wiring and Controller

Charging current is array watts divided by battery voltage. The table uses 54 V and full rated output; expect about 0.75 of that after losses.

Array Wiring Controller Controller limit on 48 V Charging current at 54 V
350 W, one panel, Vmp 43 V or less Single panel Genasun GVB-8 (boost) 8 A input, 350 W 6.5 A
400 W, four 100 W 12 V panels 4 in series Victron MPPT 100/20 or 150/35 20 A, 1,160 W or 35 A, 2,000 W 7.4 A
900 W, two 450 W 72-cell panels 2 in series Victron MPPT 150/35 35 A, 2,000 W 17 A
1,800 W, four 450 W panels 2 strings of 2 in series Victron MPPT 150/35 35 A, 2,000 W 33 A
3,600 W, eight 450 W panels 4 strings of 2 in series Victron MPPT 150/70 70 A, 4,000 W 67 A

The 100/20's 100 V limit leaves room only for the 144-cell string. With parallel strings, keep the total short-circuit current under the controller's limit: 35 A for the 150/35, 50 A for the 150/70. Victron lists some 150/85 VE.Can part numbers (SCC115085412, SCC115085512) as 12/24 V only, so check the label.

Worked Example: Daily Harvest and Running Time for an Elco EP-14 or EP-20

Elco lists its EP-9.9, EP-14 and EP-20 outboards and its EP-12 and EP-20 inboards as 48 V systems. An older Elco sheet shows an earlier EP-20 inboard on 72 V, so check the nameplate.

Assumptions:

  • Array: 900 W, two panels in series on an MPPT 150/35.
  • Sun: 5 equivalent full sun hours per day, the yearly-average example in the sizing guide. Use 2.5 for winter.
  • System factor: 0.75 for panel heat, flat mounting, wiring and controller losses.
  • Motor draw equal to the power setting shown.

Daily harvest = 900 W × 5 h × 0.75 = 3,375 Wh, about 3.4 kWh. Running time is harvest divided by motor power:

  • EP-14 at its continuous rating of 6.2 kW: 0.54 hours, about 33 minutes.
  • EP-20 at its continuous rating of 8.4 kW: 0.40 hours, about 24 minutes.
  • Either motor throttled back to 2 kW: 1.7 hours; at 1 kW: 3.4 hours.

Distance is hours times speed. If your boat holds 4 knots at 2 kW, 1.7 hours is about 7 nautical miles (8 statute miles). The speed is an assumption; check yours on a battery monitor.

Elco's battery options include a 48 V 120 Ah lithium pack (6.0 kWh) for the EP-14 and a 210 Ah pack (10.5 kWh) for the EP-20. At 3.4 kWh per day the array refills them from empty in about 2 and 3 sunny days.

Charging Profile: 48 V Lithium Versus Lead-Acid

On a 48 V bank Victron's default lead-acid profile charges to 57.6 V in absorption and floats at 55.2 V, while its LiFePO4 preset charges to 56.8 V for a fixed 2 hours, floats at 54 V and disables equalization and temperature compensation. Genasun sets its units at the factory: 57.6 V bulk, 56.8 V absorption and 55.2 V float for lead-acid, a constant 56.8 V for lithium. Treat these as starting points, set the voltages your battery maker specifies, and make sure a lithium bank has a BMS that can disconnect the charger.

Wiring and Safety on a 48 V System

The path is panels, PV disconnect, controller, fuse, battery. A 48 V nominal bank reaches about 58 V while charging, and a series array can exceed 100 V in sunlight. Victron says these connections must be guarded against contact.

  • Voltage ratings. Every fuse, breaker and switch must be DC-rated above the highest voltage it will see. Genasun notes that automotive blade fuses are typically rated to 32 V and recommends a 58 V fuse for its 48 V models.
  • Battery fuse. Victron specifies 40 to 45 A for the 150/35, 80 to 100 A for the 150/70 and 100 to 120 A for the 150/85. Genasun requires a fast-acting fuse or breaker of 10 A or less close to the battery.
  • Fuse position. Elco's manual places the fuse at the battery, within 7 inches of it, or within 40 inches if the cable runs in a sheath or enclosure.
  • PV disconnect. Victron requires a means to disconnect all current-carrying conductors of the array.
  • Connection order. Victron: battery first. Genasun: panel first.

Elco advises a propulsion bank separate from the house bank and an ABYC-certified electrician. Follow the manuals and ABYC E-11 (electrical systems), E-13 (lithium batteries) and E-30 (electric propulsion).

Which Setup Suits Which Boat

  • Launch, skiff or small daysailer with room for one panel: up to 350 W on a Genasun GVB-8, the WP version if exposed to spray.
  • Pontoon boat or trailer sailer with 40 to 50 sq ft of canopy: two large panels in series on an MPPT 150/35, the layout of the 48V kit.
  • Cruising sailboat or power catamaran with 80 sq ft or more: two series strings on an MPPT 150/35 up to 2,000 W, and an MPPT 150/70 above that.
  • Sailboat with mast or boom shade: one boost controller per panel, so one shaded panel does not pull down a string.

Questions & Answers

What size 48V solar charge controller do I need?

Divide array watts by battery voltage to get charging current, then pick a controller rated higher. A 900 W array at 54 V gives about 17 A, so a Victron MPPT 150/35 (35 A) fits. The array's cold-weather open-circuit voltage must also stay under its 150 V input limit.

Can one solar panel charge a 48V battery bank?

Yes, with a boost controller. The Genasun GVB-8 steps up the voltage of a single panel of up to 350 W with a maximum power voltage of 43 V or less. A standard step-down MPPT cannot do this, because it needs an array voltage 5 V above battery voltage to start.

How many solar panels does a 48 volt solar charger need?

With a standard MPPT, Victron's manuals require at least 144 cells in series on a 48 V battery: four 12 V panels with 36 cells each, or two 24 V panels with 72 cells each. On a 150 V controller the maximum is 216 cells: six 12 V or three 24 V panels.

How long does a 48V solar battery charger take to refill an electric boat bank?

Multiply array watts by daily sun hours and by 0.75 for losses. A 900 W array with 5 sun hours yields about 3.4 kWh per day. That refills a 6.0 kWh lithium pack from empty in about 2 sunny days. With 2.5 sun hours in winter the harvest halves and the time doubles.