Inverter Bypass Switch: What It Is and How It Is Wired

An inverter bypass switch lets you power your AC circuits directly from shore power or a generator, around the inverter. You need it when the inverter fails or has to be removed for service. This guide explains what the switch does, how it is wired, and what to check before buying one.

What Is an Inverter Bypass Switch?

In a typical boat or RV system, shore or generator power feeds the inverter (or inverter charger), and the inverter output feeds the AC panel. If the inverter fails, everything behind it goes dark, even when shore power is available. A bypass switch is a manual selector with two working positions:

  • Normal (Inverter): AC input goes to the inverter, and the inverter output feeds the loads. The inverter charges the batteries and its internal transfer switch passes shore power through when it is available.
  • Bypass: AC input goes straight to the loads. The inverter is disconnected from both its input and its output, so it can be removed or repaired while the circuits stay powered.

Many switches also have an Off position between the two.

Bypass Switch vs the Inverter's Internal Transfer Switch

Most inverter chargers already contain an automatic transfer relay. It switches the loads to shore power when shore power is present and back to the inverter when it is lost. That relay is inside the inverter, so it does not help when the inverter itself has failed or has been removed. An external bypass switch is the manual backup for that case.

How an Inverter Bypass Switch Is Wired

The switch sits between the AC source, the inverter and the AC load panel:

  1. The AC source (shore power inlet breaker or generator) connects to the switch's source terminals.
  2. In the Normal position, the switch connects the source to the inverter's AC input and connects the inverter's AC output to the load panel.
  3. In the Bypass position, the switch connects the source directly to the load panel and disconnects the inverter's output.

Important points for a safe installation:

  • Break-before-make. The switch must disconnect one source before connecting the other. Inverter output must never be connected to shore power or a generator: that can destroy the inverter and back-feed the dock.
  • Switch the neutral as well as the hot. On boats, the hot and the neutral are normally both switched (two poles for 120 V; three poles for 120/240 V split-phase). Grounding conductors are never switched.
  • Current rating. Rate the switch for at least the larger of the shore power breaker and the inverter's AC pass-through current, for example 30 A or 50 A.
  • Follow the diagrams. Use the switch maker's wiring diagram and the inverter manual. On boats, follow ABYC E-11; in RVs, follow the applicable electrical code. AC wiring is dangerous: if you are not qualified, have a marine electrician install it.

When You Need One

  • Your loads run through an inverter charger, and you want shore power to keep working if the inverter fails.
  • You want to service or replace the inverter without rewiring.
  • You are installing a larger system where downtime is a problem, such as a liveaboard boat, a charter vessel or an off-grid cabin.

Some manufacturers offer bypass kits for their own equipment, such as the OutBack FW500 bypass kit. eMarine also stocks a general inverter bypass switch. Confirm its ratings against your system before installing it.

Related Guides