Victron Energy

Victron Skylla-TG Marine Battery Charger | GL & GMDSS Models

Skip to product information
1 of 16
Models

Regular price $679.15
Sale price $679.15 Regular price $799.00
SKU: BCV60633
MPN: SDTG2400301

Questions about compatibility? Call us for help.

Get an additional off

Add the item to cart to apply the discount

Ships in 1-2 business days

Carrier delivery times and cost shown at checkout.

The Victron Skylla-TG is a professional-grade, high-frequency, microprocessor-controlled battery charger range designed for demanding marine, commercial, and industrial applications. Available across 13 configurations spanning 24V and 48V output, single-phase and three-phase AC input, standard and universal (GL-approved) input voltage models, and GMDSS-certified maritime safety variants, the Skylla-TG is the most comprehensive and specification-intensive charger range in the Victron product family.

All Skylla-TG models use an IUoUo three-stage charging algorithm - Bulk (constant current), Absorption (constant voltage, timed 4 hours), and Float (constant voltage, 20 hours) - controlled by a microprocessor for precise, battery-safe charging across all battery types. The absorption time can be shortened to 30 minutes via a switch position for partially discharged batteries. A battery temperature sensor is included with every model and connects to the charger for automatic temperature-compensated charging - reducing charge voltage as battery temperature rises to prevent overcharging and gassing in warm environments.

All 24V models feature two isolated outputs: the main (house) output delivering the full rated charge current, and a second output limited to approximately 4A at a slightly lower voltage for simultaneously topping up a starter battery - with the exception of the 24/100 (3-phase) and 48V single-output models. Voltage sense terminals compensate for cable resistance losses, ensuring the battery always receives the correct charge voltage regardless of cable length.

The GL-approved (Germanischer Lloyd) models operate over a universal 90-265V AC input range at 50 or 60Hz and also accept a 90-400V DC supply - making them suitable for worldwide use on any AC or DC supply. Standard 230V models operate over 185-265V AC. Three-phase models accept 320-450V. GMDSS models are certified to IEC 60945 maritime navigation and radiocommunication equipment standards, with a built-in battery controller providing battery time-to-go prediction via the separately ordered VE.Net GMDSS panel.

Features

IUoUo Three-Stage Microprocessor-Controlled Charging

The IUoUo algorithm delivers precise Bulk, Absorption, and Float charging under microprocessor control - charging faster and more safely than conventional chargers while protecting all battery types from overcharging. Absorption time is switchable between 4-hour full and 30-minute partial cycle modes for batteries that do not require a complete recharge.

Battery Temperature Sensor Included - Temperature-Compensated Charging

Every Skylla-TG is supplied with a battery temperature sensor that connects directly to the charger and automatically reduces charge voltage as battery temperature rises - essential protection for sealed VRLA batteries that cannot tolerate overcharging in warm engine rooms or equipment compartments.

Dual Outputs - House Battery and Starter Battery (24V Models)

All 24V models except the 3-phase variants feature two isolated outputs: the full-rated main house battery output and a dedicated approximately 4A starter battery output at a slightly lower voltage - enabling simultaneous charging and maintenance of both battery banks from a single charger.

Battery Voltage Sense - True At-Battery Regulation

Voltage sense terminals on all models compensate for voltage drop across the charge cables — ensuring the battery always receives the correct absorption and float voltage regardless of cable length, cross-section, or connection resistance.

GL-Approved Universal Input Models (90–265V AC / DC)

The GL-approved variants operate without adjustment across the full 90-265V AC input range at 45-65Hz and also accept a 90-400V DC supply - making them suitable for worldwide shore power, generator, and DC bus operation. Certified by Germanischer Lloyd to environmental category C, EMC 1, and IEC 60945-2002 for bridge equipment.

GMDSS Models - Maritime Safety System Compliance

The GMDSS variants include a built-in battery controller providing time-to-go prediction and all monitoring and alarm data required by the Global Maritime Distress and Safety System (GMDSS) - displayed via the separately ordered VE.Net GMDSS remote panel. Certified to IEC 60945 maritime navigation and radiocommunication equipment standard.

Three-Phase Models for High-Power Shore Connections

The 24/50 and 24/100 three-phase models accept a 320-450V three-phase AC input, providing high-capacity charging from three-phase shore power connections as found on commercial vessels and industrial facilities - with the same IUoUo algorithm and temperature compensation as single-phase models.

DC Power Supply Capability

The precisely regulated output voltage of all Skylla-TG models allows them to be used as a DC power supply when no battery is connected - powering DC loads directly from the AC input at the charger's rated output voltage and current.

Specifications
Model Input Voltage Input Range (VAC) Input Range (VDC) Charge Current (House) Charge @ 110VAC Starter Batt. Absorption Float Rec. Battery Weight Dimensions (h×w×d)
Skylla-TG 24/30 (1+1) 120-240V 120 / 230V 95-264V 120-400V 30A 30A 4A 28.5V 26.5V 150-500 Ah 5.5 kg 365 × 250 × 147 mm
Skylla-TG 24/50 (1+1) 230V 230V 185-264V 180-400V 50A 30A 4A 28.5V 26.5V 150-500 Ah 5.5 kg 365 × 250 × 147 mm
Skylla-TG 24/80 (1+1) 230V 230V 185-264V 180-400V 80A 60A 4A 28.5V 26.5V 400-800 Ah 10 kg 365 × 250 × 247 mm
Skylla-TG 24/100 (1+1) 230V 230V 185-264V 180-400V 100A 60A 4A 28.5V 26.5V 500-1000 Ah 10 kg 365 × 250 × 257 mm
Skylla-TG 24/50 (1+1) 3-Phase 400V 3 × 400V 320-450V N/A 50A N/A 4A 28.5V 26.5V 250-500 Ah 13 kg 365 × 250 × 257 mm
Skylla-TG 24/100 (1+1) 3-Phase 400V 3 × 400V 320-450V N/A 100A N/A N/A 28.5V 26.5V 500-1000 Ah 23 kg 515 × 260 × 265 mm
Skylla-TG 24/30 (1+1) GL 120-240V 120 / 230V 90-265V 90-400V 30A 22A 4A 28.5V 26.5V 150-300 Ah 5.5 kg 365 × 250 × 147 mm
Skylla-TG 24/50 (1+1) GL 120-240V 120 / 230V 90-265V 90-400V 50A 30A 4A 28.5V 26.5V 250-500 Ah 5.5 kg 365 × 250 × 147 mm
Skylla-TG 24/100 (1+1) GL 120-240V 120 / 230V 90-265V 90-400V 100A 60A 4A 28.5V 26.5V 500-1000 Ah 10 kg 365 × 250 × 257 mm
Skylla-TG 24/30 GMDSS 120-240V 120 / 230V 90-265V N/A 30A (22A @ 110V) 22A N/A 28.5V 26.5V N/A 6 kg 485 × 250 × 147 mm
Skylla-TG 24/50 GMDSS 120-240V 120 / 230V 90-265V N/A 50A 30A N/A 28.5V 26.5V N/A 6 kg 485 × 250 × 147 mm
Skylla-TG 48/25 (1) 230V 230V 185-264V 180-400V 25A 15A N/A 57V 53V 125-250 Ah 5.5 kg 365 × 250 × 147 mm
Skylla-TG 48/50 (1) 230V 230V 185-264V 180-400V 50A 30A N/A 57V 53V 250-500 Ah 10 kg 365 × 250 × 257 mm

Common Specifications - All Models: Charge algorithm: IUoUo (3-stage) | Frequency: 45–65 Hz | Power factor: 1 | Remote alarm: Potential-free contacts 60V/1A (1× NO and 1× NC) | Forced cooling: Yes | Operating temperature: −40°C to +50°C (full output up to +40°C) | Humidity: max 95% non-condensing | Enclosure: Aluminium blue RAL5012 | Battery connection: M8 studs | Protection rating: IP21 | Protections: Output short-circuit, battery reverse polarity detection, battery voltage too high, temperature too high

Datasheets and Manuals

Datasheet - Standard 24V & 48V Models

Datasheet - GL Universal Input Models

Datasheet - GMDSS Models

Product Manual - 24/30 Universal Input

Product Manual - 24/50

Product Manual - 24/80, 24/100, 48/25, 48/50