Galvanic Isolator for Boats: How It Works and How to Install It

A galvanic isolator protects the underwater metals on your boat from corrosion caused through the shore power cord. This guide explains why plugging in causes corrosion, how an isolator works, how to choose and install one, and when an isolation transformer is the better choice.

Why Shore Power Causes Galvanic Corrosion

When you plug into shore power, the green grounding wire of the cord connects your boat's grounding and bonding system, and through it the propeller, shaft, through-hulls, outdrive and zincs, to the marina's ground. Every other boat plugged into the same dock is connected to that ground too. The boats now form one large battery through the water: dissimilar metals on different hulls produce small DC voltages and currents between them. The least noble metal, usually your zincs and then your propeller or outdrive, corrodes. Boats at a marina often eat through anodes much faster than boats on a mooring.

How a Galvanic Isolator Works

A galvanic isolator is installed in series in the shore power green grounding wire, between the shore power inlet and the boat's ground. Inside are diodes connected in both directions. Diodes do not conduct until the voltage across them reaches a threshold of roughly 1.2–1.4 V, depending on the design. The galvanic voltages between metals in seawater are lower than that, so the isolator blocks the small DC currents that cause corrosion. If an AC fault puts a high voltage on the ground, the diodes conduct immediately and pass the fault current to shore. The safety ground keeps doing its job: tripping breakers and protecting people from shock.

Choosing a Galvanic Isolator

  • Current rating: at least the rating of your shore power service, for example 30 A or 50 A. One 50 A isolator can usually serve two 30 A cords when their grounds are joined before the isolator.
  • Fail-safe design: a fail-safe isolator is designed to fail "closed", so you lose corrosion protection but keep the safety ground. ABYC A-28 requires a status monitor unless the isolator is a fail-safe type; check what your model needs.
  • Hull material: aluminum hulls are especially vulnerable, and some isolators are made specifically for them. Compare the Hypertech Galvanic Isolator for fiberglass and wooden boats with the Hypertech Galvanic Isolator Plus for aluminum boats.
  • Environment: potted, waterproof units such as the Victron Galvanic Isolator (16, 32 or 64 A) can be mounted in bilges and engine rooms.

Installing a Galvanic Isolator

  1. Disconnect the shore power cord before starting.
  2. Mount the isolator close to the shore power inlet.
  3. Remove the green ground wire from the inlet. Connect one isolator lead to the inlet's ground terminal and the other lead to the boat's ground wire.
  4. Make sure no other ground path bypasses the isolator to shore, otherwise it cannot work.
  5. Test the isolator with a meter's diode-test function after installation. Test it again once a season and after any lightning strike or electrical fault.

This is part of the boat's AC safety ground. If you are not familiar with AC wiring, have a qualified marine electrician install it.

Galvanic Isolator vs Isolation Transformer

A galvanic isolator is compact, inexpensive and needs no power. Its one limit is that the boat is still connected to the marina ground through it. An isolation transformer, such as the Victron 7000 W Isolation Transformer, transfers power magnetically. The boat has no direct connection to shore ground at all. It also protects against faulty or reversed dock wiring and against stray currents larger than an isolator can block. It is larger, heavier and more expensive, which is why it is mostly fitted on larger yachts, steel and aluminum boats, and liveaboards.

Browse all galvanic isolators. For the boat's DC grounding and bonding, see Grounding Solar PV Systems on a Boat and Boat Electrical System Design.