What Size Inverter Do I Need for My Boat? Inverter vs Inverter Charger
Size a marine inverter to the total running watts of the AC loads you will use at the same time, plus a margin, and check that its surge rating can start any motor or compressor. On 12 V, 1,000 W suits electronics, 2,000 W runs one galley appliance at a time, and about 3,000 W is the practical limit before 24 V or 48 V makes more sense. Choose an inverter charger if the boat also uses shore power or a generator.
Step 1: Add Up the Continuous Watts
List each 120 V appliance you want to run from the batteries and read its watts from the nameplate. If it gives amps only, multiply by 120. Add up only the loads that run together: a coffee maker and a microwave used one at a time count as the larger of the two.
The figures below come from the appliance tables that Magnum, Xantrex and Go Power publish for inverter sizing. They are typical ranges; check your own nameplate.
| AC load | Typical running watts | Motor or compressor |
|---|---|---|
| Laptop charger | 25–150 W | No |
| Flat-screen TV | 65–150 W | No |
| Power drill | 250–750 W | Yes |
| Blender | 400–1,000 W | Yes |
| Refrigerator (120 V AC) | About 500 W | Yes |
| Coffee maker | 800–1,200 W | No |
| Toaster | 800–1,500 W | No |
| Hair dryer | 900–1,600 W | No |
| Microwave oven | 1,000–2,000 W | No |
| Hot plate | 1,800 W | No |
Air conditioners and watermakers vary too much for a typical figure, so use their nameplate amps. Xantrex advises adding at least 50% to the total to cover peaks. Compare watts, not VA, at the temperature of the space where the unit will sit: Victron rates its 3,000 VA MultiPlus-II at 2,400 W at 77°F (25°C) and 2,200 W at 104°F (40°C).
Step 2: Check Surge Watts for Motors and Compressors
Motors and compressors draw far more than their running watts at start-up, as much as five times their rated power according to Xantrex. For a compressor, the locked rotor amps (LRA) on the nameplate times 120 gives a worst case.
Compare that number with the inverter's surge rating. A refrigerator that runs at 500 W could need up to 2,500 W to start. The Xantrex Freedom X 1000 surges to 2,000 W for 5 seconds and may not start it. The Freedom X 2000 surges to 4,000 W and has room to spare.
Step 3: Work Out the DC Current
The DC current sets the cable, the fuse and the battery bank:
DC amps = AC watts ÷ battery volts ÷ efficiency
Worked example: 2,000 W ÷ 12 V ÷ 0.85 = 196 A. Xantrex lists 192 A at full load for the Freedom X 2000. Current rises as battery voltage sags, and Magnum lists a maximum continuous input of 267 A for the 2,000 W MS2012. Take the cable size and fuse rating from the inverter manual, not from the formula.
For energy, a 1,500 W hair dryer used for 6 minutes takes 150 Wh, about 15 Ah from a 12 V bank. Total a day with the energy usage calculator.
Marine Inverter Size Chart: 1000, 2000, 3000 and 5000 W
| Inverter size | What it runs | DC amps at 12 V | DC amps at 24 V | Victron bank, 12 V | Victron bank, 24 V |
|---|---|---|---|---|---|
| 1000 W | Laptops, TV, chargers, a blender or a drill | 98 A | 49 A | 150 Ah minimum | 60 Ah minimum |
| 2000 W | One galley appliance at a time, plus electronics | 196 A | 98 A | 350–1,000 Ah | 200–500 Ah |
| 3000 W | Two heating appliances, or a microwave with a refrigerator | 294 A | 147 A | 400–1,200 Ah | 200–700 Ah |
| 5000 W | Several heavy loads at once on a larger boat | 490 A | 245 A | 800–2,400 Ah | 400–1,400 Ah |
DC amps are full-load figures from the formula at nominal voltage and 85% efficiency. The bank columns are what Victron's manuals recommend for the Inverter VE.Direct 1200 (1,000 W), Inverter Smart 2000 (1,600 W), MultiPlus-II 3000 (2,400 W) and Quattro 5000 (4,000 W), rated at 77°F (25°C). Victron names its models in VA, so each delivers less than the first column. Treat these banks as the low end.
Magnum's rule for its MS series is simpler: at least 200 Ah for loads under 1,000 W and more than 400 Ah for 1,000 W and above, discharged no more than 50% as a general rule. With lithium, also check that the battery's continuous discharge limit exceeds the inverter's full-load DC amps.
When 12 V Stops Making Sense: 24 V or 48 V
For the same watts, a 24 V bank carries half the current of a 12 V bank and a 48 V bank a quarter. Victron's wiring guide recommends 12 V for inverters up to 3,000 VA, 24 V up to 5,000 VA, and 48 V from 5,000 VA up.
Cable size shows why. Magnum's 12 V MS2012 needs 2/0 AWG for a run of 5 feet or less in free air, while the 24 V MS2024 needs #4 AWG. For a 5,000 VA Quattro, Victron specifies an 800 A fuse and two 120 mm² cables per terminal at 12 V, against a 200 A fuse and one 70 mm² cable at 48 V. Above about 3,000 W of load, plan the house bank at 24 V or 48 V and feed 12 V equipment from a DC-DC converter. See the marine wire gauge guide.
Inverter vs Inverter Charger
A plain inverter only turns battery DC into 120 V AC. The Victron Inverter VE.Direct 12/1200 (called Phoenix in older documents) gives 1,000 W with a 2,200 W peak and has no charger or transfer switch. The Xantrex Freedom X adds a built-in 30 A transfer relay that hands the outlets to shore power when it is present.
A marine inverter charger adds two things in one case:
- A battery charger, sized to match: 50 A in the Magnum MMS1012, 100 A in the MS2012 and 150 A in the Xantrex Freedom XC PRO 3000. Victron advises a charge current of 10% to 20% of the bank's amp-hours, so set it to suit the bank and the battery maker's limit.
- An automatic transfer switch. It passes shore or generator power to the loads while the charger runs, and returns to inverting when that power drops. Magnum lists a 16 millisecond minimum transfer time, and Victron less than 20 milliseconds for the Quattro.
On shore power and generators, the charger is itself an AC load: Magnum lists 15 A AC for the MS2012 at full charge, which counts on a 30 A cord or a small generator. Pass-through is limited too, to 30 A per input on the Magnum MS series. The Victron Quattro has two AC inputs, for shore power and a generator, and connects to whichever is live. Brand differences are in Victron vs Magnum vs Xantrex.
A plain inverter is enough when the boat already has a good shore charger, never plugs in, or feeds only one or two outlets. Its output must never share a circuit with shore power unless a transfer relay or a break-before-make switch separates them, as the inverter bypass switch guide explains. Install either type by the manufacturer's manual and ABYC E-11 and A-31.
Which Marine Inverter or Inverter Charger Suits Which Boat
- Day boat or small sailboat, 12 V, no shore power: a plain pure sine inverter of about 1,000 W for laptops, a TV and chargers.
- Boat with a good shore charger already: a plain inverter with a transfer relay, such as the Xantrex Freedom X (1,000, 2,000 or 3,000 W, 12 V).
- Coastal cruiser, 12 V, 30 A shore power: a 2,000 W inverter charger such as the Magnum MS2012 with more than 400 Ah of battery. DMX Power, which now sells the Magnum line, lists the MS2012 as superseded by the MS2012-L.
- Liveaboard on 12 V: a 3,000 W class inverter charger, with cabling for about 300 A.
- Larger yacht or loads above 3,000 W: a 24 V or 48 V bank with a 4,000 to 5,000 VA unit, such as the Magnum MS4024-L or the Victron Quattro 5000.
Questions & Answers
What size inverter do I need for my boat?
Add the nameplate watts of the AC loads that will run at the same time, then add a margin; Xantrex suggests at least 50%. Make sure the surge rating covers motor start-up. As a guide, 1,000 W suits electronics, 2,000 W runs one galley appliance at a time, and 3,000 W runs two. On 12 V, a 2,000 W inverter draws close to 200 A at full load.
Inverter charger vs inverter: what is the difference?
A plain inverter only turns battery power into 120 V AC. An inverter charger adds a battery charger and an automatic transfer relay in the same case. When shore or generator power is present, it passes that power to the outlets and charges the batteries, and when the power drops it switches back to inverting. A boat that plugs in or runs a generator regularly is better served by an inverter charger.
Can a 12 V boat run a 3000 W inverter charger?
Yes. The Xantrex Freedom XC PRO 3000 is a 12 V inverter charger rated 3,000 W at 104°F (40°C), with a 150 A charger and 304 A DC at full load. The Victron MultiPlus-II 12/3000 gives 2,400 W at 77°F (25°C), and Victron specifies a 400 A fuse and a 400 to 1,200 Ah bank for it. The battery cables must be short and heavy.
Is there a 5000 W marine inverter, and in which voltages?
Victron lists the 120 V Quattro 5000 inverter charger in 12 V, 24 V and 48 V versions, and the 120 V MultiPlus-II 5000 in 24 V and 48 V only. The 5000 is a VA rating: continuous output is 4,000 W at 77°F (25°C). The 12 V Quattro needs an 800 A fuse and an 800 to 2,400 Ah bank, so 24 V or 48 V is the usual choice at this size.
How many batteries do I need for a 2000 W inverter?
Magnum recommends more than 400 Ah for loads of 1,000 W and above, and Victron recommends 350 to 1,000 Ah for its 12 V, 2,000 VA inverter. Four 100 Ah, 12 V batteries in parallel are a starting point. Run time is a separate check: watts times hours, divided by battery volts and by 0.85, gives the amp-hours each load takes.